Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Wuhan Qiaoxin Refrigeration Equipment Co., Ltd. Shell and Tube Heat Exchanger Expert

Manufacturer from China
Active Member
9 Years
Home / Products / Shell And Tube Condenser /

Air Cooled Heat Pump Unit R134a Shell And Tube Condenser

Contact Now
Wuhan Qiaoxin Refrigeration Equipment CO., LTD
City:wuhan
Province/State:hubei
Country/Region:china
Contact Person:MrsNichole Deng
Contact Now

Air Cooled Heat Pump Unit R134a Shell And Tube Condenser

Ask Latest Price
Video Channel
Brand Name :GREEFOUN
Model Number :QXC65
Certification :CE, ROSH
Place of Origin :CHINA
MOQ :1piece
Payment Terms :TT, L/C, Western Union
Supply Ability :100000pieces/year
Delivery Time :within 20days
Packaging Details :Standard Export Package
Application :Air cooled heat pump industry
Shell material :Carbon steel
Tube medium :Water
Capacity range :18kw~3000kw
Refrigerant :R410A
Type :Shell and tube type
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Air Cooled Heat Pump Unit Industrial Condenser

Water Cooled Condenser

Air-cooled heat pump unit is a cold and heat source equipment, is the atmosphere as a heat source of a

heat pump system, when the water as a heat source called water source heat pump, with the earth as a

heat source called ground source heat pump. It is a hot and cold two with the equipment.

Air-cooled heat pump unit is a cold and heat source to provide an independent complete unit, but also the

use of air around the natural energy, coupled with air-cooled heat pump manufacturing process and other

characteristics, which has many characteristics:

1, installed in the outdoors, such as roofs, balconies, etc., do not occupy an effective building area,

saving civil construction investment.

2, summer cooling, winter heating, eliminating the boiler room, favorable for urban construction.

3, save the cooling water system and cooling towers, cooling pumps, pipe network and its water treatment

equipment, saving this part of the investment and operating costs.

4, the winter heating energy-saving, that is, heat pump heating than direct electricity to save about two-

thirds.

5, security and automatic control at the same time installed in a body, reliable operation, easy

management.

6, independent and complete unit, easy installation, can shorten the construction period.

Details drawing and technical data are as below:

DRAWING

Air Cooled Heat Pump Unit R134a Shell And Tube Condenser

CONDENSER SERIES DOUBLE CIRCUIT

CAPACITY: 10RT TO 40RT

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C C2 E
QXC10D6 10 3.78 168 483 1065 75 185 233 92 78 7.8
QXC15D6 15 5.67 168 635 1369 75 185 233 92 85 11.6
QXC20D6 20 7.56 168 819 1737 90 185 233 92 96 15.8
QXC25D6 25 9.45 219 819 1755 90 238 285 113 132 19.5
QXC30D6 30 11.34 219 819 1755 90 238 285 113 137 23
QXC35D6 35 13.23 219 819 1755 90 238 285 113 145 27.3
QXC40D6 40 15.12 219 953 2024 90 238 285 113 162 31

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread) FPT(inner pipe thread)
QXC10D6 1/4 5/8 5/8 1-1/2
QXC15D6 1/4 7/8 5/8 1-1/2
QXC20D6 1/4 7/8 5/8 1-1/2
QXC25D6 1/4 1-1/8 7/8 2
QXC30D6 1/4 1-1/8 7/8 2-1/2
QXC35D6 1/4 1-3/8 7/8 2-1/2
QXC40D6 1/4 1-3/8 7/8 2-1/2

CONDENSER SERIES DOUBLE CIRCUIT

CAPACITY: 50RT TO 200RT

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC50D10A 50 18.9 273 953 2364 90 360 150 350 240 265 38.5
QXC60D10A 60 22.68 273 953 2364 90 360 150 350 240 279 46
QXC70D12A 70 26.46 325 953 2377 90 406 180 350 240 359 53.5
QXC80D12A 80 30.24 325 953 2377 90 406 180 350 240 375 61
QXC100D12A 100 37.80 325 953 2377 90 406 180 350 240 409 76
QXC120D12A 120 45.36 325 1270 3011 120 406 180 350 240 481 91
QXC140D14A 140 52.92 355 1270 3018 120 440 200 350 240 553 106
QXC160D16A 160 60.48 426 1600 3656 120 510 260 310 310 723 120.6
QXC200D16A 200 75.60 426 1600 3656 120 510 260 310 310 777 150.8

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread) Male flange
QXC50D10A 3/8 1-3/8 7/8 DN65
QXC60D10A 3/8 1-5/8 1-1/8 DN65
QXC70D12A 3/8 1-5/8 1-1/8 DN80
QXC80D12A 3/8 1-5/8 1-1/8 DN80
QXC100D12A 3/8 2-1/8 1-3/8 DN100
QXC120D12A 3/8 2-1/8 1-3/8 DN100
QXC140D14A 3/8 2-1/8 1-3/8 DN100
QXC160D16A 3/8 2-5/8 1-3/8 DN125
QXC200D16A 3/8 2-5/8 1-5/8 DN125

CONDENSER SERIES DOUBLE CIRCUIT

CAPACITY: 220RT TO 426RT

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC220D16A 220 78.55 426 1430 3656 120 530 260 310 310 830 165.8
QXC240D16A 240 81.65 426 1430 3656 120 530 260 310 310 890 181
QXC260D20A 260 84.36 480 1600 3800 150 530 280 310 310 953 195.5
QXC280D20A 280 88.24 480 1600 3800 150 530 280 350 240 1016 211
QXC320D20A 320 95.21 480 1600 3800 180 600 300 350 240 1098 240.6
QXC340D22A 340 98.68 530 1750 4000 180 600 300 350 240 1162 256
QXC380D22A 380 106.53 530 1750 4000 200 650 300 400 320 1253 285.5
QXC426D22A 426 115.62 530 1900 4000 200 650 300 420 350 1325 320

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread) Male flange
QXC220D16A 3/8 2-5/8 1-5/8 DN125
QXC240D16A 3/8 2-5/8 1-5/8 DN125
QXC260D20A 3/8 2-5/8 1-5/8 DN125
QXC280D20A 3/8 3-1/8 2-1/8 DN150
QXC320D20A 3/8 3-1/8 2-1/8 DN150
QXC340D22A 3/8 4-1/8 2-1/8 DN150
QXC380D22A 3/8 4-1/8 2-1/8 DN200
QXC426D22A 3/8 4-1/8 2-1/8 DN250


COOPERATED CLENTS

Air Cooled Heat Pump Unit R134a Shell And Tube Condenser


Inquiry Cart 0