Add to Cart
Water Cooling Tube Heat Exchanger
Stainless Steel Evaporator for Chiller
Stainless steel heat transfer tube has the following advantages:
heat exchanger with 0.5-0.8mm thin-walled pipe to improve the overall heat transfer performance, in the
same heat transfer area, the overall heat transfer coefficient than the copper increased 2.121-8.408%
As the material used SUS304 high-quality stainless steel alloy, it has a high hardness, the pipe's steel is
also significantly improved, therefore, has a strong impact resistance and anti-vibration performance.
As the inner wall of the pipe is smooth, the thickness of the underlying laminar flow is thinned, which
enhances the heat transfer and improves the anti-fouling performance.
In order to eliminate the welding stress, in the protective gas to 1050 ℃ high temperature heat
treatment.
steel pipe are used to carry out leakage pressure check, air pressure test to 10MPa, 5 minutes without
pressure drop.
STAINLESS STEEL EVAPORATOR
STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR
CAPACITY: 750KW TO 1500KW
Models | RE750S14 | RE900S16 | RE1100S16 | RE1240S20 | RE1360S20 | RE1420S20 | RE1500S20 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C | Qn | KW | 750 | 900 | 1100 | 1240 | 1360 | 1420 | 1500 |
Kcal/h (×103 ) | 700 | 862 | 983 | 1076 | 1169 | 1258 | 1367 | ||
Wn | m3 /h | 121 | 141 | 168 | 230 | 252 | 261 | 289 | |
Wm | m3 /h | 136 | 158 | 176 | 261 | 275 | 309 | 328 | |
Dpn | bar | 0.48 | 0.54 | 0.48 | 0.40 | 0.46 | 0.49 | 0.58 |
Models | RE750S14 | RE900S16 | RE1100S16 | RE1240S20 | RE1360S20 | RE1420S20 | RE1500S20 | |
Dimension (mm) | A | 170 | 170 | 170 | 190 | 190 | 190 | 190 |
B | 377 | 426 | 426 | 480 | 480 | 480 | 480 | |
C | 3000 | 2860 | 3000 | 2860 | 2860 | 3000 | 3500 | |
D | 460 | 530 | 530 | 600 | 600 | 600 | 600 | |
E | 400 | 450 | 450 | 500 | 500 | 500 | 550 | |
F | 3086 | 2984 | 3124 | 2984 | 2984 | 3124 | 3624 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 150 | 150 | 150 | 200 | 200 | 200 | 200 |
D1(mm) | 42 | 42 | 42 | 54(2) | 54(2) | 54(2) | 54(2) | |
D2(mm) | 92 | 92 | 92 | 108 | 108 | 108 | 108 | |
P(kg) | 706 | 753 | 808 | 863 | 921 | 992 | 1069 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
U SHAPED TUBE DRY EVAPORATOR (DOUBLE CIRCUIT)
CAPACITY: 120KW TO 310KW
Models | QXU120D8 | QXU135D8 | QXU155D8 | QXU185D10 | QXU220D10 | QXU270D10 | QXU310 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C | Qn | KW | 120 | 135 | 155 | 185 | 220 | 270 | 310 |
Kcal/h (×103 ) | 103.2 | 116 | 133.3 | 159 | 189 | 232 | 267 | ||
Wn | m3 /h | 20.6 | 23.2 | 26.7 | 31.8 | 37.8 | 46.4 | 53.3 | |
Wm | m3 /h | 25 | 28 | 30 | 41 | 43 | 65 | 68 | |
Dpn | bar | 0.41 | 0.44 | 0.37 | 0.36 | 0.43 | 0.42 | 0.43 |
Models | QXU120D8 | QXU135D8 | QXU155D8 | QXU185D10 | QXU220D10 | QXU270D10 | QXU310D | |
Dimension (mm) | A | 1815 | 2115 | 2315 | 2320 | 2320 | 2654 | 2654 |
B | 219 | 219 | 219 | 219 | 273 | 273 | 273 | |
C | 200 | 200 | 200 | 200 | 234 | 234 | 234 | |
D | 1530 | 1830 | 2030 | 2000 | 2000 | 2280 | 2280 | |
E | 240 | 240 | 240 | 300 | 300 | 300 | 300 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 89 | 89 | 89 | 89 | 114 | 114 | 114 |
D1(mm) | 22 | 22 | 22 | 22 | 35 | 35 | 35 | |
D2(mm) | 42 | 42 | 42 | 42 | 54 | 54 | 54 | |
P(kg) | 145 | 155 | 163 | 232 | 255 | 279 | 296 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 75RT TO 100RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC75S12A | 75 | 28.350 | 325 | 2032 | 2485 | 120 | 360 | 180 | 350 | 240 | 335 | 57.2 |
QXC80S12A | 80 | 30.240 | 325 | 2032 | 2485 | 120 | 406 | 180 | 350 | 240 | 343 | 61 |
QXC85S12A | 85 | 32.130 | 325 | 2032 | 2485 | 120 | 406 | 180 | 350 | 240 | 350 | 64.1 |
QXC90S12A | 90 | 34.020 | 325 | 2032 | 2485 | 120 | 406 | 180 | 350 | 240 | 364 | 68 |
QXC95S12A | 95 | 35.910 | 325 | 2032 | 2485 | 120 | 406 | 180 | 350 | 240 | 372 | 72.1 |
QXC100S12A | 100 | 37.800 | 325 | 2500 | 2966 | 120 | 406 | 180 | 350 | 240 | 379 | 76 |
Model | S (Vent) | P (fluoride inlet) Copper pipe diameter (inch) | L(fluoride outlet) Copper pipe diameter (inch) | W (standard port) | W (optional port) |
FPT(inner pipe thread) | Male flange | Male flange | |||
QXC75S12A | 3/8 | 2-1/8 | 1-3/8 | DN80 | DN100 |
QXC80S12A | 3/8 | 2-1/8 | 1-3/8 | DN80 | DN100 |
QXC85S12A | 3/8 | 2-5/8 | 1-3/8 | DN100 | DN100 |
QXC90S12A | 3/8 | 2-5/8 | 1-3/8 | DN100 | DN100 |
QXC95S12A | 3/8 | 2-5/8 | 1-3/8 | DN100 | DN100 |
QXC100S12A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
COOPERATED CLENTS